Advanced configuration
Component
Requirement
Message text
Specify required message text for the SMS notification. Message
text must only contain the following characters: a-z, A-Z, 0-9 as well
as commas (,) and full stops (.). Note that camera information, date
and time information are all automatically included in SMS
notifications.
Variables
Click a link to include a variable to the notification. The options are:
Name of triggering event
Camera name
Trigger time (the time when the notification was registered)
Error text (for example, camera failure)
Ignore similar messages for:
Specify the number of seconds to ignore sending similar
notifications. This function is to ensure that you do not receive too
many notifications before you have solved the relevant problem.
Use schedule profile
Select the schedule profile you want to use. By default, you can
choose between Always On, Always Off or choose Add new... to
set up a custom schedule (see "Notification Scheduling properties"
on page 149).
Server Settings (SMS)
Specify the following server settings for SMS:
Component
Requirement
Serial port
Select the serial port to use for your USB/3G modem. The list from
which you can choose ports shows open serial ports on the
computer running your system.
Speed
The baud speed of your USB modem device. The default value is
9600 baud. Although you can set any custom value for the baud
rate, Milestone does not recommend that you change the baud rate
unless you are a highly advanced user.
SIM card PIN code
Specify PIN code for the SIM card inserted in the USB/3G modem.